We recommend the basic variants of the Elite detectors, the TEXECOM and Tecnoalarm manufacturers for outdoor applications of motion detectors (the perimeter protection).
The Elite-EXT-TD-B detector is a PIR scanner with two sensors; the range and sensitivity are adjustable, it has the day/night modes, supplied in white or black version.
The outdoor dual Elite Orbit DT detector is a combined PIR + MW detector with a large range, in an elegant design for wall mounting.
Trired is an outdoor triple PIR detector manufactured by Tecnoalarm, with the curtain characteristics, anti-masking protection and anti-opening and anti-detachment tamper. It features an adjustable detection of masking and range for each beam.
Tab. 1. The basic parameters of the Elite and TRIRED outdoor motion detectors
Type |
External TD |
Elite Orbit DT |
TRIRED |
Order number |
031 32000 (white) |
031 32101 |
031 74600 |
The principle of detection |
mirro technology, two PIR sensors |
digital technology PIR+MW |
Tripple PIR detector |
range |
Adjustable 2, 5, 8, 12 m |
Adjustable 10, 20, 30 m |
30 m |
Detection angle |
90 ° |
90 ° |
|
Rotating optics |
180 ° |
180 ° |
|
Sensitivity adjustment |
2 to 4 pulses (adjustable) |
1 to 2 pulses (adjustable) |
|
Alarm output |
NC, max. 100 mA |
2x, NO and NC, max. 50 mA |
NC, max. 50 mA |
Sabotage contact |
NC, max. 100 mA |
NC |
NC, max. 50 mA |
LED indication |
yes |
yes |
|
Temperature comensation |
yes |
yes |
|
Supply voltage |
9 ÷ 16 VDC |
9 ÷ 15 VDC |
10.5 ÷ 14.5 VDC |
Consumption |
28 mA |
15 mA |
27 mA |
Operating temperature |
-35 to + 55 °C |
-20 to + 60 °C |
-25 to + 65 °C |
Operating humidity |
max. 95 % |
max. 95 % |
max. 95 % |
Assembly, the height |
on the wall, typically 1.0 ÷ 1.4 m |
on the wall, typically. 1.5 ÷ 6 m |
on the wall, typically. 1.35 ÷ 2.2 m |
Dimensions |
250 x 86.5 x 87 mm |
141 x 165.5 x 109 mm |
82 x 400 x 260 mm |
The casing colour |
White or black |
silver |
White |
The weight |
500 g |
300 g |
1.3 kg |
Protection |
IP65 |
IP55 |
IP55 |
|
Fig. 1. An example of connecting the External TD motion detector to the C-WG-0503S module
Notes:
-
The connection assumes the use of double balanced loop; both the JP7 and JP6 jumpers in the detector must be set to 1 k resistance. (see the general description of double balancing in Chap.8.1.1).
-
Correct installation of the detectors is specified in the product operating instructions.
-
A cable with the wire diameter of at least 0.3mm can be used for the connection, e.g. the SYKFY cable; its length can be up to dozens of meters.
The Elite Orbit DT and Trired detectors are connected in the same way as e.g. the interior detectors; using double balancing, the external 1 k resistors should be connected to the ALARM and TAMPER outputs