For underground and outdoor installations, the ETHERLINE® CAT.5 FD BK cable can be used (produced by the LAPP GROUP).
The cable meets the standards EIA/TIA-568, TSB-36 and ISO/IEC IS 11801.
Tab. 1. Basic parameters
Order number |
CE217489 |
||
The minimum bend radius |
95 mm |
||
The temperature range: |
|
||
|
The mobile usage |
-5 °C to +50 °C |
|
|
Fixed installation |
-40 °C to +70 °C |
|
Wire |
Bare copper wire 0.14 mm² (19x 0.10), (26AWG) |
||
The wire insulation |
Foam PE, maximum external diameter 1.0 mm |
||
Twisting |
2 wires twisted in pairs, 4 pairs together |
||
Internal coating |
Halogen-free thermoplastic elastomer |
||
Shielding |
Braid of tinned copper wires, 85 % ± 5 covered |
||
The outer sheath |
Halogen-free PUR, black |
||
External diameter |
6.3 mm |